Catálogo de publicaciones - revistas
Acta Ophthalmologica
Resumen/Descripción – provisto por la editorial en inglés
Acta Ophthalmologica (formerly Acta Ophthalmologica Scandinavica) publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.Palabras clave – provistas por la editorial
No disponibles.
Disponibilidad
Institución detectada | Período | Navegá | Descargá | Solicitá |
---|---|---|---|---|
No detectada | desde ene. 2008 / hasta dic. 2023 | Wiley Online Library |
Información
Tipo de recurso:
revistas
ISSN impreso
1755-375X
ISSN electrónico
1755-3768
Editor responsable
John Wiley & Sons, Inc. (WILEY)
País de edición
Reino Unido
Fecha de publicación
2008-2013
Cobertura temática
Tabla de contenidos
Topical drug delivery to the eye: dorzolamide
Thorsteinn Loftsson; Phatsawee Jansook; Einar Stefánsson
Palabras clave: Ophthalmology; General Medicine.
Pp. 603-608
doi: 10.1111/aos.14198
Socio‐economic disparity in global burden of near vision loss: an analysis for 2017 with time trends since 1990
Yijie Wang; Lixia Lou; Jing Cao; Ji Shao; Juan Ye
Palabras clave: Ophthalmology; General Medicine.
Pp. No disponible
doi: 10.1111/aos.15050
Understanding the mechanism of retinal displacement following rhegmatogenous retinal detachment repair: A computer simulation model
Armin Farahvash; Samara B. Marafon; Verena R. Juncal; Natalia Figueiredo; Arun Ramachandran; Rajeev H. Muni
<jats:title>Abstract</jats:title><jats:sec><jats:title>Purpose</jats:title><jats:p>Retinal displacement is common following rhegmatogenous retinal detachment (RRD) repair. A computer simulation was developed to assess forces applied by a gas tamponade of various sizes in the setting of pneumatic retinopexy (PnR) versus pars plana vitrectomy (PPV).</jats:p></jats:sec><jats:sec><jats:title>Design</jats:title><jats:p>Computer simulation model.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>The contact angle and pressure between the tamponade and the retina were calculated using interfacial tension and the densities of gas and vitreous. A simulation determined the dynamics of fluid motion in the subretinal space and calculated deformations of the retina.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Bulk flow of fluid away from the tamponade in a direction along gravity stretched the retina and caused displacement in the simulations. Extent of displacement is attributable to the subretinal fluid layer thickness, and area of contact and contact pressure applied by the tamponade. Larger gas tamponades have greater contact pressure applied to the retina. Reducing gas bubble size from 93% to 6.25% with PPV versus PnR, there was a 79% reduction in the mean contact pressure (1.4 mmHg–0.29 mmHg), and a 93% reduction in the surface area of contact (11 cm<jats:sup>2</jats:sup>–0.8 cm<jats:sup>2</jats:sup>). Therefore, the contact force applied to the entire retina decreases by 97% from 83 mN (PPV) to 2.9 mN (PnR). The model resembling PnR had more than three times less displacement compared to PPV.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>This model provides a framework to study retinal displacement. Our findings suggest that proportional to their size, gas tamponades stretched the retina by displacing subretinal fluid following RRD repair.</jats:p></jats:sec>
Palabras clave: Ophthalmology; General Medicine.
Pp. No disponible