Catálogo de publicaciones - revistas

Compartir en
redes sociales


Acta Ophthalmologica

Resumen/Descripción – provisto por la editorial en inglés
Acta Ophthalmologica (formerly Acta Ophthalmologica Scandinavica) publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
Palabras clave – provistas por la editorial

No disponibles.

Disponibilidad
Institución detectada Período Navegá Descargá Solicitá
No detectada desde ene. 2008 / hasta dic. 2023 Wiley Online Library

Información

Tipo de recurso:

revistas

ISSN impreso

1755-375X

ISSN electrónico

1755-3768

Editor responsable

John Wiley & Sons, Inc. (WILEY)

País de edición

Reino Unido

Fecha de publicación

Cobertura temática

Tabla de contenidos

Topical drug delivery to the eye: dorzolamide

Thorsteinn Loftsson; Phatsawee Jansook; Einar Stefánsson

Palabras clave: Ophthalmology; General Medicine.

Pp. 603-608

Socio‐economic disparity in global burden of near vision loss: an analysis for 2017 with time trends since 1990

Yijie WangORCID; Lixia Lou; Jing Cao; Ji Shao; Juan YeORCID

Palabras clave: Ophthalmology; General Medicine.

Pp. No disponible

Understanding the mechanism of retinal displacement following rhegmatogenous retinal detachment repair: A computer simulation model

Armin Farahvash; Samara B. Marafon; Verena R. Juncal; Natalia FigueiredoORCID; Arun Ramachandran; Rajeev H. MuniORCID

<jats:title>Abstract</jats:title><jats:sec><jats:title>Purpose</jats:title><jats:p>Retinal displacement is common following rhegmatogenous retinal detachment (RRD) repair. A computer simulation was developed to assess forces applied by a gas tamponade of various sizes in the setting of pneumatic retinopexy (PnR) versus pars plana vitrectomy (PPV).</jats:p></jats:sec><jats:sec><jats:title>Design</jats:title><jats:p>Computer simulation model.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>The contact angle and pressure between the tamponade and the retina were calculated using interfacial tension and the densities of gas and vitreous. A simulation determined the dynamics of fluid motion in the subretinal space and calculated deformations of the retina.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Bulk flow of fluid away from the tamponade in a direction along gravity stretched the retina and caused displacement in the simulations. Extent of displacement is attributable to the subretinal fluid layer thickness, and area of contact and contact pressure applied by the tamponade. Larger gas tamponades have greater contact pressure applied to the retina. Reducing gas bubble size from 93% to 6.25% with PPV versus PnR, there was a 79% reduction in the mean contact pressure (1.4 mmHg–0.29 mmHg), and a 93% reduction in the surface area of contact (11 cm<jats:sup>2</jats:sup>–0.8 cm<jats:sup>2</jats:sup>). Therefore, the contact force applied to the entire retina decreases by 97% from 83 mN (PPV) to 2.9 mN (PnR). The model resembling PnR had more than three times less displacement compared to PPV.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>This model provides a framework to study retinal displacement. Our findings suggest that proportional to their size, gas tamponades stretched the retina by displacing subretinal fluid following RRD repair.</jats:p></jats:sec>

Palabras clave: Ophthalmology; General Medicine.

Pp. No disponible